SMSC Simulator Adapter

Introduction

The Spotfire Streaming Short Message Service Center (SMSC) Simulator Adapter is bundled with our SMPP Adapter, and is used to simulate a real connection.

Adapter Properties

This section describes the properties you can set for this adapter using the various tabs of the Properties view in StreamBase Studio.

General Tab

Name: Use this required field to specify or change the name of this instance of this component. The name must be unique within the current EventFlow module. The name can contain alphanumeric characters, underscores, and escaped special characters. Special characters can be escaped as described in Identifier Naming Rules. The first character must be alphabetic or an underscore.

Adapter: A read-only field that shows the formal name of the adapter.

Class name: Shows the fully qualified class name that implements the functionality of this adapter. If you need to reference this class name elsewhere in your application, you can right-click this field and select Copy from the context menu to place the full class name in the system clipboard.

Start options: This field provides a link to the Cluster Aware tab, where you configure the conditions under which this adapter starts.

Enable Error Output Port: Select this checkbox to add an Error Port to this component. In the EventFlow canvas, the Error Port shows as a red output port, always the last port for the component. See Using Error Ports to learn about Error Ports.

Description: Optionally, enter text to briefly describe the purpose and function of the component. In the EventFlow Editor canvas, you can see the description by pressing Ctrl while the component's tooltip is displayed.

Operator Properties Tab

Property Type Description
Port string Port number for the SMSC server to use.
System ID string The system ID (username) for verifing a SMPP connection.
Password string The password for connecting for verifing a SMPP connection.

Cluster Aware Tab

Use the settings in this tab to enable this operator or adapter for runtime start and stop conditions in a multi-node cluster. During initial development of the fragment that contains this operator or adapter, and for maximum compatibility with releases before 10.5.0, leave the Cluster start policy control in its default setting, Start with module.

Cluster awareness is an advanced topic that requires an understanding of StreamBase Runtime architecture features, including clusters, quorums, availability zones, and partitions. See Cluster Awareness Tab Settings on the Using Cluster Awareness page for instructions on configuring this tab.

Concurrency Tab

Use the Concurrency tab to specify parallel regions for this instance of this component, or multiplicity options, or both. The Concurrency tab settings are described in Concurrency Options, and dispatch styles are described in Dispatch Styles.

Caution

Concurrency settings are not suitable for every application, and using these settings requires a thorough analysis of your application. For details, see Execution Order and Concurrency, which includes important guidelines for using the concurrency options.

Control Port

Description

Use the control port to send action commands to the adapter. Tuples enqueued on this port start or stop the adapter to the message center.

Control Port Schema

Field Data Type Description
command string The command tells the adapter what action to take. Available commands are connect, disconnect, and list.

Control Status Output Port

Field Data Type Description
Status string The name of the status.
Message string Status message.

The following lists all available status:

  • SERVER START—Server started.

  • SERVER STOP—Server stopped.

  • Error—An error occurred.

  • INVALID COMMAND—The command is invalid.

Related Topics