This article provides a reference for writing a LiveView Client API Listener
configuration file where the HOCON type is com.tibco.ep.ldm.configuration.ldmclientapilistener
.
The LiveView client API listener configuration defines port numbers and secure communication indicators. It is separate from the base StreamBase engine configuration and can therefore be managed separately without having to recreate an application archive and redeploy the application whenever (for example) a port number changes.
Each configuration file must contain the following header lines, typically found at the beginning of each file:
- name
-
Specifies an arbitrary, case-sensitive string to name this configuration, which must be unique among other files with the same type, if any. Configuration files can refer to each other by this name. Select a name that reminds you of this configuration's type and purpose. For example:
name = "my-ldm-api-settings"
- version
-
Specifies an arbitrary version number that you can use to keep track of file versions for this configuration type in your development project. The maintenance of version numbers is under user control; StreamBase does not compare versions when loading configuration files during the fragment launch process. The version number is a string value, and can contain any combination of characters and numbers. For example:
version = "1.0.0"
- type
-
This essential setting specifies the unique HOCON configuration type described on this page.
type = "com.tibco.ep.ldm.configuration.ldmclientapilistener"
The three header lines taken together constitute a unique signature for each HOCON
file in a project's configurations
folder. Each
project's configurations
folder can contain only one
file with the same signature.
The top-level configuration
object defines the
configuration envelope the same way for all HOCON file types.
- configuration
-
On a line below the header lines, enter the word
configuration
followed by an open brace. Theconfiguration
object is a sibling of thename
,version
, andtype
identifiers, and serves to define the configuration envelope around this type's objects as described on this page. The file must end with the matching close brace.configuration = { ... ... }
Below shows the configuration's HOCON properties, usage, and syntax example, where applicable.
- ClientAPIListener
-
Root object for the LiveView Client API listener configuration settings.
- associatedWithEngines
-
If you want to manually restrict this object to be associated with specific engines, do so here. Each entry can be a specific engine name or a regular expression that can apply to more than one engine. This array is optional and has no default value. If not present, the configuration uses a default engine association based on its location in a fragment or application archive, or in a node deploy configuration.
For example:
associatedWithEngines = [ "javaengine", "otherengine[0-9]" ]
- portNumber
-
Specifies the TCP port on which the current LiveView engine is to listen for client connections. The port range is 1025 – 65535, inclusive. A zero value directs the LiveView engine to find a random unused port to listen on.
Starting with TIBCO Streaming 10.6.0, the client connection port for LiveView is determined as follows:
-
Both in Studio and on the command line with epadmin, a port specified in a configuration file with this ClientAPIListener > portNumber property is always honored first.
-
If there is no configuration definition, the LiveView engine tests port 10080 and uses it, if available.
-
If that port is busy, the engine tries 10081 and uses it, if available.
-
If that port is busy, the engine tries 10082 and so on.
-
For Studio launches, once a port is selected, Studio communicates that port to the Runtime.
If your project has architectural or legacy reasons to specify a particular port, use this ClientAPIListener > portNumber property in a configuration file in the Studio project's
/src/main/configurations
folder at node installation time.For a running node, you can upload but cannot activate a configuration that specifies a portNumber. The engine that has affinity with the configuration must be stopped to activate such a configuration.
For example:
portNumber = 10080
Note that the Client API listener port for EventFlow fragments is determined with a different algorithm, as described on this page.
Note
In previous TIBCO Streaming releases, the default value of 10080 was set for connections to be made with
lv://
orhttp://
, and 10443 for connections to be made withlvs://
orhttps://
. Those defaults and the distinction for the connecting protocol are no longer valid. -
- authenticationRealmName
-
Authentication realm associated with this listener, indicating that user authentication is to be performed for requests handled by this listener. This realm name is specified in the com.tibco.ep.dtm.configuration.security file.
This optional property has no default value. When you provide one, LiveView server authentication is enabled for the realm.
For example:
authenticationRealmName = "my-realm"
- secureCommunicationProfileName
-
Name of a secure communication server profile to use when configuring secure communication for a listener. The profile must be defined in the
secureCommunicationProfileName
property in a separate configuration file of type com.tibco.ep.dtm.configuration.security.This property is optional and has no default value. If not present, the listener will not use secure connections with its clients.
For example:
secureCommunicationProfileName = "my-secure-communication-client-profile"
The following shows an example of the com.tibco.ep.ldm.configuration.ldmclientapilistener type.
name = "clientApiListener" version = "1.0.0" type = "com.tibco.ep.ldm.configuration.ldmclientapilistener" configuration = { ClientAPIListener = { portNumber = 10080 authenticationRealmName = "authRealm" secureCommunicationProfileName = "my-secure-communication-client-profile" } }