Contents
This topic explains AggregateByTup.sbapp
, the Aggregate
operator tuple dimension sample.
This sample demonstrates two uses of the tuple-based Aggregate operator. The first uses a tuple-based Aggregate operator to calculate a moving average of price for each of four successive trades of a given stock. It also ensures that the aggregation works for intermixed tuples for different stocks. The second provides a sequence number for input tuples, using a window which does not close and the emit feature to emit an output tuple for every input tuple.
In StreamBase Studio, import this sample with the following steps:
-
From the top-level menu, click
> . -
Enter
sample group
to narrow the list of options. -
Select Operator sample group from the Data Constructs and Operators category.
-
Click
.
StreamBase Studio creates a single project for the operator samples.
-
In the Project Explorer view, open the sample you just loaded.
If you see red marks on a project folder, wait a moment for the project to load its features.
If the red marks do not resolve themselves after a minute, select the project, right-click, and select
> from the context menu. -
Open the
src/main/eventflow/com.tibco.sb.sample.operator
folder. -
Open the
AggregateByTup.sbapp
file and click the Run button. This opens the SB Test/Debug perspective and starts the module. -
In the Output Streams view, select the AvgPricePSOut output stream. No output is displayed at this point, but the dequeuer is prepared to receive output. This view will eventually show the output of the application.
-
In the Manual Input view, select the TradesIn input stream.
-
Enter
AMAT
and23
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe that no output is displayed yet in the Output Streams view. -
Enter
AMAT
and24
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe that no output is displayed yet in the Output Streams view. -
Again enter
AMAT
and24
in the Symbol, and PricePerShare fields, respectively. -
Click
. There is still no output in the Output Streams view. -
Enter
AMAT
and25
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe this line in the Output Streams view:Symbol=AMAT, MovingAverage=24.0
Tip
If output data is too long to easily see in the Output Streams grid, click a row to display its field data in the Display Fields pane below the table.
-
Enter
AMAT
and20
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe this line in the Output Streams view:Symbol=AMAT, MovingAverage=23.25
-
Enter
AMAT
and21
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe this line in the Output Streams view:Symbol=AMAT, MovingAverage=22.5
-
Enter
AMAT
and21
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe this line in the Output Streams view:Symbol=AMAT, MovingAverage=21.75
-
Enter
AMAT
and22
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe this line in the Output Streams view:Symbol=AMAT, MovingAverage=21.0
-
Enter
INTC
and27
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe no further output is displayed yet in the Output Streams view. -
Enter
INTC
and28
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe no further output is displayed yet in the Output Streams view: -
Enter
AMAT
and22
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe this line in the Output Streams view:Symbol=AMAT, MovingAverage=21.5
-
Enter
INTC
and27
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe no further output is displayed yet in the Output Streams view: -
Enter
AMAT
and23
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe this line in the Output Streams view:Symbol=AMAT, MovingAverage=22.0
-
Enter
INTC
and28
in the Symbol, and PricePerShare fields, respectively. -
Click
, and observe this line in the Output Streams view:Symbol=INTC, MovingAverage=27.5
-
Next, view the sequence number.
-
In the Output Streams view, select the SeqOut output stream. No output is displayed at this point, but the dequeuer is prepared to receive output.
-
Change from Manual Input to the Feed Simulations view.
-
Right click on
SeqFeed.sbfs
and select . -
Notice on output how sequence_number increases by
1
. -
When done, press F9 or click the Terminate EventFlow Fragment button.
When you load the sample into StreamBase Studio, Studio copies the sample project's files to your Studio workspace, which is normally part of your home directory, with full access rights.
Important
Load this sample in StreamBase Studio, and thereafter use the Studio workspace copy of the sample to run and test it, even when running from the command prompt.
Using the workspace copy of the sample avoids permission problems. The default workspace location for this sample is:
studio-workspace
/sample_operator
See Default Installation
Directories for the default location of studio-workspace
on your system.